Dell PowerVault NX3500 User Manual

Page 43

Advertising
background image

About Your Solution

43

The following

DIMMs should

match

in

geometry:

x,x,...

Invalid memory

configuration. The specified

memory modules do not

match in size, number of

ranks, or number of

data lanes.

Ensure that the memory

modules are installed in a

valid configuration.

See "General Memory

Module Installation

Guidelines" on page 67.

The following

DIMMs should

match

in rank

count:

x,x,...

The following

DIMMs should

match in size:

x,x,...

The following

DIMMs should

match

in size

and geometry:

x,x,...

The following

DIMMs should

match

in size

and rank count:

x,x,...

Thermal sensor

not detected on

x.

A memory module without a

thermal sensor is installed in

the specified memory slot.

Replace the memory

module. See "System

Memory" on page 66.

Time-of-day

clock stopped.

Faulty battery or faulty chip. See "Troubleshooting the

System Battery" on page 95.

Time-of-day not

set - please run

SETUP program.

Incorrect Time or Date

settings; faulty system

battery.

Check the Time and Date

settings. If the problem

persists, replace the system

battery. See "System Battery"

on page 79.

Timer chip

counter 2 failed.

Faulty system board.

See "Getting Help" on

page 113.

Table 1-4. System Messages

(continued)

Message

Causes

Corrective Actions

book.book Page 43 Monday, January 24, 2011 12:24 PM