About Your Solution

41

Plug & Play

Configuration

Error.

Error encountered in

initializing PCIe device;

faulty system board.

Install the NVRAM_CLR

jumper in the clear position

(pins 1 and 3) and reboot the

system. See Figure 5-1 for

jumper location. If the

problem persists,

see "Troubleshooting an

Expansion Card" on

page 101.

Quad rank DIMM

detected after

single rank or

dual rank DIMM in

socket.

Invalid memory

configuration.

Ensure that the memory

modules are installed in a

valid configuration.

See "General Memory

Module Installation

Guidelines" on page 67.

Read fault.

Requested sector

not found.

The operating system cannot

read from the hard drive,

optical drive, or USB device,

the system could not find a

particular sector on the disk,

or the requested sector is

defective.

Replace the optical medium,

USB medium, or USB

device. Ensure that the USB

cables, SAS/SATA backplane

cables, or optical drive cables

are properly connected.

See "Troubleshooting an

Optical Drive" on page 99, or

"Troubleshooting a Hard

Drive" on page 100 for the

appropriate drive(s) installed

in your system.

SATA Port x

device not

found.

There is no device connected

to the specified SATA port.

Information only.

Table 1-4. System Messages

(continued)

Message

Causes

Corrective Actions