Dell PowerVault NX3500 User Manual

Page 40

Advertising
background image

40

About Your Solution

Memory tests

terminated by

keystroke.

POST memory test was

terminated by pressing the

spacebar.

Information only.

MEMTEST lane

failure detected

on x.

Invalid memory

configuration. Mismatched

memory modules are

installed.

Ensure that the memory

modules are installed in a

valid configuration.

See "General Memory

Module Installation

Guidelines" on page 67.

No boot device

available.

Faulty or missing optical

drive subsystem, hard drive,

or hard drive subsystem, or

no bootable USB key

installed.

Use a bootable USB key,

optical drive, or hard drive.

If the problem persists,

see "Troubleshooting an

Optical Drive" on page 99,

and "Troubleshooting a Hard

Drive" on page 100.

No boot sector on

hard drive.

Incorrect configuration

settings in System Setup

program, or no operating

system on hard drive.

Check the hard drive

configuration settings in the

System Setup program.

If necessary, install the

operating system on your

hard drive. See your

operating system

documentation.

No timer tick

interrupt.

Faulty system board.

See "Getting Help" on

page 113.

PCIe Training

Error: Expected

Link Width is x,

Actual Link Width

is y.

Faulty or improperly

installed PCIe card in the

specified slot.

Reseat the PCIe card in the

specified slot number.

See "Troubleshooting an

Expansion Card" on

page 101. If the problem

persists, see "Getting Help"

on page 113.

Table 1-4. System Messages

(continued)

Message

Causes

Corrective Actions

book.book Page 40 Monday, January 24, 2011 12:24 PM

Advertising