Dell PowerVault NX3500 User Manual

Page 27

Advertising
background image

About Your Solution

27

E161C

Power Supply #

(### W) lost

AC power.

Check PSU

cables.

Specified power supply is

attached to the system,

but it has lost its

AC input.

Check the AC power

source for the specified

power supply. If the

problem persists, see

"Troubleshooting Power

Supply" on page 96.

E1620

Power Supply #

(### W) AC

power error.

Check PSU

cables.

Specified power supply's

AC input is outside of the

allowable range.

Check the AC power

source for the specified

power supply. If the

problem persists, see

"Troubleshooting Power

Supply" on page 96.

E1624

Lost power

supply

redundancy.

Check PSU

cables.

The power supply

subsystem is no longer

redundant. If the

remaining power supply

fails, the system will

shut down.

See "Troubleshooting

Power Supply" on

page 96.

E1626

Power Supply

Mismatch. PSU1

= ### W, PSU2

= ### W.

The power supplies in

the system are not the

same wattage.

Ensure that power

supplies with matching

wattage are installed.

See the Technical

Specifications outlined in

your system’s Getting

Started Guide.

E1629

Power required

> PSU wattage.

Check PSU and

config.

The system configuration

requires more power than

the power supplies can

provide, even with

throttling.

Turn off power to the

system, reduce the

hardware configuration or

install higher-wattage

power supplies, and then

restart the system.

Table 1-3. LCD Status Messages

(continued)

Code

Text

Causes

Corrective Actions

book.book Page 27 Monday, January 24, 2011 12:24 PM