Dell PowerVault NX3500 User Manual
Page 42

42
About Your Solution
Sector not found.
Seek error.
Seek operation
failed.
Faulty hard drive.
Replace the hard drive.
Ensure that the SAS
backplane cables are properly
connected. See
Drive" on page 100 for the
appropriate drive(s) installed
in your system.
Shutdown
failure.
General system error.
The amount of
system memory has
changed.
Memory has been added or
removed or a memory
module may be faulty.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module.
See "Troubleshooting
Table 1-4. System Messages
(continued)
Message
Causes
Corrective Actions
book.book Page 42 Monday, January 24, 2011 12:24 PM