About Your Solution

Sector not found.

Seek error.

Seek operation

failed.

Faulty hard drive.

Replace the hard drive.

Ensure that the SAS

backplane cables are properly

connected. See

"Troubleshooting a Hard

Drive" on page 100 for the

appropriate drive(s) installed

in your system.

Shutdown

failure.

General system error.

See "Getting Help" on

page 113.

The amount of

system memory has

changed.

Memory has been added or

removed or a memory

module may be faulty.

If memory has been added or

removed, this message is

informative and can be

ignored. If memory has not

been added or removed,

check the SEL to determine

if single-bit or multi-bit

errors were detected and

replace the faulty memory

module.

See "Troubleshooting

System Memory" on page 97.