3-21

4 W D D Y N O I N S T A L L A T I O N

Cable Routing

Version 1

Above Ground Model 424x/424xLC

2

Automotive Dynamometer Installation Guide

10 Route the air hose (P) from the T fitting on the air brake can on the stationary

dyno to your clean dry air supply. Refer to “Installing the Air Fittings” on page 2-
14
for more information.
The air brake comes installed with a hose barb for a 3/8-inch inside diameter air
hose. If your hose does not have an inside diameter of 3/8-inch then you will need
an air hose nipple (1/4-inch NPT) to connect your clean, dry shop air supply to the
dyno. Once the pressure is connected, the air brake is ready to use.

11 Route the drum brake air hose (R) from the cable track to the air brake can on the

stationary dyno.

12 Route the rail brake air hose (Q) from the second cable track to the T fitting on the

air brake can on the stationary dyno.
The air brake comes installed with a hose barb for a 3/8-inch inside diameter air
hose. If your hose does not have an inside diameter of 3/8-inch then you will need
an air hose nipple (1/4-inch NPT) to connect your clean, dry shop air supply to the
dyno. Once the pressure is connected, the air brake is ready to use.

13 Route the hydraulic pump power cable (G) from the first cable track and connect

to a 110VAC or 220VAC outlet. The pump motor is wired for 110VAC, refer to
Figure 3-19 on page 3-30 for more information on wiring the hydraulic pump
motor.

14 Route the 4WD board power cable (N) from the first cable track and connect to

the power supply. Plug the power supply cable (B) into your power source.

15 Route the eddy current brake driver power cable (I) from the eddy current brake

driver on the stationary dyno to your power source. Plug the power cable into your
power source. Refer to Appendix B for power requirements.
Route the eddy current brake driver power cable (I) from the first cable track to
your power source. Plug the power cable into your power source. Refer to
Appendix B for power requirements.

16 Route the dyno movement pendant cable (O) from the second cable track and

connect to the pendant.

17 Connect the IR temperature sensor cables (L) to the eddy current brake drivers.
18 Connect the load cell cables (M) to the eddy current brake drivers.
19 Connect the controller cables (E) from the eddy current brake to the eddy current

brake drivers.

20 Connect the CAN pendant cable (F) to the DynoWare RT module.
21 Connect the primary/secondary pickup cable (H) to the DynoWare RT module.
22 Connect the remote atmos cable (D) to the DynoWare RT module.
23 Connect the ethernet cable (C) to your DynoWare RT module and connect to your

network. Refer to “Network Connections” on page 1-15 for more information.

24 Connect the power cable (A) to the DynoWare RT module. Plug the power cable

into your power source.

Advertising