16






R E L I A N C E S T O R M M A X I N S T A L L A T I O N M A N U A L

2.2 a. Attach horizontal members as shown in 2.1.

b. Cut HW-130 glazing adaptor to same size as horizontal member as shown in 1.8.

c. Drill #9 (.1960") fastener holes 12" OC and 1" off ends and counter sink at "V" grooves.

d. Drill a hole and dry fit HW-130 glazing adaptor to horizontal member.

e. Install FG-5185 interior spacer gasket cut to same length as HW-130 glazing adaptor.

f. Bed reglet with Dow Corning 795 silicone sealant.

g. Fasten HW-130 with FS-119 fastener. Seal screw head with 795 silicone sealant

Bed riglet with Dow Corning 795

Silicone Sealant

FG-5185 Spacer Gasket

HW-130 Glazing Adaptor

FS-119 Fastener

9/16" GLAZING ADAPTOR INSTALLATION (OPTIONAL)

FIGURE 2.2