R E L I A N C E S T O R M M A X I N S T A L L A T I O N M A N U A L

PRODUCT USE

The Reliance StormMax curtain wall system is intended for installation by glazing professionals

with appropriate experience. Subcontractors without experience should employ a qualified person

to provide field instruction and project management.

Oldcastle BuildingEnvelope does not control the application or selection of its product

configurations, sealant or glazing material and assumes no responsibility thereof. It is the

responsibility of the owner, architect and installer to make these selections in strict compliance

with applicable laws and building codes.

Consult sealant manufacturer for review and recommendation of sealant application.

Follow sealant manufacturer's recommendations and literature for proper

installation.

The air and water performance of the Reliance StormMax curtain wall system is directly related to

the completeness and integrity of the installation process both the seal installed at the shear

blocks and the glazing gasket installed at the interior side of the glass. All pressure plates must

also be installed properly. To insure top performance for this system, particular attention should

be given the following procedures:

1. Surfaces to be sealed should be cleaned with isopropyl alcohol or solvent and dried as

recommended by sealant manufacturer to remove all dirt and cutting oils. Sealant at shear

blocks should be a minimum 3/16" diameter nominal placed completely around the top, face

and bottom of the shear block without gaps in the sealant. Exposed surfaces should be

cleaned after installing the horizontal. Inspect joint for complete sealant contact, especially

where the horizontal meets the face of the vertical member. Repair joint as required.

2. The exterior glazing gasket should be installed so as to avoid stretching, buckles or tears.

Variations on the details shown are inevitable and are not the responsibility of Oldcastle

BuildingEnvelope when drawn by others. Oldcastle BuildingEnvelope strongly encourages its

customers to use its Engineering department for calculations and shop drawings.