Jamb-fabrication – Oldcastle BuildingEnvelope Reliance StormMax User Manual

Page 9

Advertising
background image

6






R E L I A N C E S T O R M M A X I N S T A L L A T I O N M A N U A L

HW-200-01 anchor sleeve

(for design pressures above 70 psf)

HW-500 jamb mullion

HW-183-01

shear block

(4) FS-9

fasteners

(2) FS-320 drive screw

HW-338 jamb end cap

Apply sealant bed to entire

length of jamb mullion

HW-122 jamb filler

FS-322

fastener

locate 12" o.c.

1.3 a. Prior to HW-183-01 shear block attachment insert HW-200-01 anchor sleeves at jamb ends and match

drill .191 dia. hole. (this step is only required for design pressures above 70 psf.)

b. Attach HW-183-01 shear block to HW-500 jamb with FS-9 fastener.

c. Attach HW-122 jamb filler to HW-500 jamb using FS-322 fastener locate 12" o.c. (drill #11 - .191" clear hole in

HW-122 jamb filler and #25 - .1495" pilot hole in jamb) HW-122 filler should be bed in sealant.

tool sealant on gap space between HW-122 filler and jamb mullion.

d. Install interior FG-5185 spacer gasket cut to 2" from ends and 2" gaps at horizontal to allow for

zone plugs.

e. Install, seal and tool HW-338 end caps to top and bottom of jamb screw boss with

(2) FS-320 #10 x 1/2" drive screws.

Apply sealant bed to front edge of

mullion end prior to installation of

HW-338 mull cap

Apply sealant bed to entire front

edge of mullion end prior to

installation of HW-338 jamb cap

2"

Gap dimension for

WW-352 zone plug

FIGURE 1.3

JAMB FABRICATION

Apply sealant bed to

entire edge of mullion

end prior to installation

of HW-338 mull cap

Advertising