R E L I A N C E S T O R M M A X I N S T A L L A T I O N M A N U A L
4.0 a. Attach steel tap plate to HW-500 jamb mullion with FS-259 fastener see Figure 4.0.
b. Install plumb and align vertical jamb mullion. Drill appropriate sized holes for anchor bolts as shown on
approved shop drawings.
c. Insert a (minimum) 1/16" Koralath slip pad between the anchor and the tap plate prior to inserting
fasteners.
NOTE: Details shown are to used as a guide only. See approved shop drawings for actual conditions.
MID POINT ANCHOR AT JAMB PANEL FRAME
FIGURE 4.0
Steel Angle Dead
Load Anchor
Wind Load Anchor
similar
Steel Tap Plate
Korolath Slip Pad
FS-259 Fastener
Type "F" Anchor Bolt
Refer to approved shop
drawings for required
fastener size.