29






R E L I A N C E S T O R M M A X I N S T A L L A T I O N M A N U A L






a. Curtain wall verticals and door subframes run through to finished floor. Bed adjacent curtain wall verticals

in sealant and anchor to floor per approved shop drawings. See shop drawings for anchoring door

jamb mullion.

b.

SUBFRAME INSTALLATION:

b.1

Assemble door subframe including TH-57 threshold.

b.2

Install subframe into curtain wall frame. Shim plumb and true.

b.3

Anchor subframe with FS-322 space 18" O.C. Anchor threshold per shop drawings

b.4

Install door stops in subframe. The vertical stops run through.

b.5

Mask off frame with painter's tape and clean & seal perimeter of frame on exterior & interior

b.6

Install door per DOOR & FRAME INSTALLATION & GLAZING MANUAL.

Put backer rod at

top of jamb subframes

and seal void

Seal joint between vertical and

horizontal subframes

View of top subframe

HW-500 Mullion

1/8" Shim Space

FS-322 Fastener 18" O.C.

1/8" Shim Space

D-226 Subframe

FG-5163 Door Stop

HW-500 Horizontal

HW-122 Pocket Filler

D-231 Door Head

ENTRANCE SUBFRAME INSTALLATION

FIGURE 3.7

Attaching Subframes

Advertising