Horiz-facecap-install – Oldcastle BuildingEnvelope Reliance StormMax User Manual

Page 30

Advertising
background image

27






R E L I A N C E S T O R M M A X I N S T A L L A T I O N M A N U A L

WW-162 cut length =

D.L.O. minus 1/4"

5/16" O weep holes locate at 1/4 points

WW-110 face cap

Weep horizontal cap

at mid-lite.

See detail below

Seal ends of pressure plate to vertical cap

7/32"

Centerline

of D.L.O

5/16" O weep hole

Horizontal Face Cap Fabrication

GP-117 gasket.

See notes below for

installation

Glazing Notes:

1. GP-117 gasket used on exterior of system.

2. Remove gaskets from reels and allow to relax overnight before installing.

3. Cut gaskets to allow minimum 1/4" per foot for any relaxation of gasket

that may occur after installation.

4. To ensure proper pressure on the glazing, 7/32" diameter holes may need to be drilled at the

ends of each horizontal pressure plate as required. locate at 1 1/2" maximum from the ends.

FS-325 screw

(FS-322 at 1/4" system)

FIGURE 3.5b

Glazing Instructions

GLAZING INSTRUCTIONS