4

SEE NOTE 4 FOR PRESSURE PLATE

& FACE CAP INSTALLATION.

CW-17

CW-1636 REF. SHT 7

FOR INSTALLATION

CW-1

CW-2

CUT LENGTH =

D.L.O. - 1/16"

CW-3

CUT LENGTH =

D.L.O. - 1/4"

CW-2

CW250-FP-108

WATER DIVERTER

1) GLASS BITE = 1/2" TYPICAL

2) CUT VERTICAL PRESSURE PLATE

1/4" SHORT AT SILL FOR WEEPAGE

(DO NOT BLOCK WITH WEATHERSEAL)

3) GLAZING GASKET: PROVIDE 1/4” ADD-

TIONAL GASKET FOR EACH FOOT OF

DAYLIGHT OPENING OT ALLOW FOR

RELAXATION OF GASKET.

1/4" SHORT

@ SILL

4) OPTION 1: INSTALL VERTICAL PRESSURE

PLATE AND FACE CAP PRIOR TO INSTALLATION

OF HORIZONTAL PRESSURE PLATES. SEAL HORIZONTAL

PRESSURE PLATE TO VERTICAL FACE CAP PRIOR

TO INSTALLING HORIZONTAL FACE CAP.

OPTION 2: INSTALL ALL PRESSURE PLATES

AND MAINTAIN A MINIMUM 1/8" SPACE BETWEEN

VERT. AND HORIZ. PRESSURE PLATES. INSTALL

VERTICAL FACE CAP AND SEAL HORIZONTAL

PRESSURE PLATE TO VERTICAL FACE CAP

PRIOR TO INSTALLING HORIZ. FACE CAP.

2

C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L

Advertising