Ssg-135isc-fabrication, Ssg 135 inside corner fabrication – Oldcastle BuildingEnvelope CW-250 User Manual

Page 64

Advertising
background image

SSG 135 INSIDE CORNER FABRICATION

64

February 2012

C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L

Web Address: www.oldcastlebe.com

Phone: 1-866-OLDCASTLE (653-2278)

2 3/4"

1 1/32"

1 1/4"

CW-161

FS-43 (TYP)

FSW-324

@ HEAD &

SILL ANCHORS

ANCHOR HOLE (by others)

#17 (.173 dia.)

DRILL THRU FOR

#12 FASTENER

TOP OF

HORIZONTAL

CW250-FP-52

CW250-FP-51

CW250-FP-50 (OPP SIDE)

CW250-FP-50

CW250-FP-51 (OPP SIDE)

1 1/4"

1 1/4"

1 1/32"

1/4"

1/2"

CW250-FP-94 MULL CAP

USE AT TOP & BOTTOM

OF MULL. ATTACH W/ FS-202

DRILL #17 (.173 dia)

CLEAR HOLE FOR

#8 FASTENER

Advertising