background image

SPLICE SEALANT INSTRUCTIONS

30

February 2012

Web Address: www.oldcastlebe.com

Phone: 1-866-OLDCASTLE (653-2278)

2 1/2"

4 1/2"

1/2" FACE CAP

SPLICE

1/2" PRES. PLT.

SPLICE

SEE NOTE #5

SEALANT INSTRUCTIONS:

1) SEAL MULLION AND SPLICE AS SHOWN IN

DETAILS 1 & 2, SHEET 28

2) INSTALL "DENVER" FOAM ROD AS SHOWN IN

DETAIL 3, SHT 29

3) APPLY NON-HARDENING NON-SKINNING

SEALANT ON TOP AND FRONT SURFACES

OF "DENVER" FOAM AS SHOWN IN

DETAIL 4, SHT. 29

4) INSTALL LOWER PRESSURE PLATE AND FILL

VOID INSIDE GLAZING CAVITY TO TOP OF

PRESSURE PLATE.

SEE DETAIL 5.

5) APPLY PREFERRED SEALANT BETWEEN

1/4" GLAZING ADAPTOR AND MULLION IN SPLICE

AREA.

6) INSTALL LOWER FACE CAP AND SEAL TO FACE

OF PRESSURE PLATE.

7) NOTE: UPPER PRESSURE PLATE AND FACE CAP

NOT SHOWN FOR CLARITY.

DETAIL 5

6

6

NOTE: SEALANT SLOPE AND

DRAIN AREA BETWEEN PRES.

PLATES AND AT LOWER FACE

CAP.

C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L

Advertising