LIVE LOAD SPLICE INSTALLATION

28

February 2012

Web Address: www.oldcastlebe.com

Phone: 1-866-OLDCASTLE (653-2278)

SEAL BETWEEN MULL

AND SPLICE SLEEVES

NOTES:

1) APPLY BOND BREAKER TAPE

AS SHOWN IN DETAIL 1 FOR LIVE

LOAD SPLICES ONLY.

2) SEAL SPACES BETWEEN SPLICE AND

MULLION AS SHOWN IN DTL 1

3) CLEAN (& PRIME IF REQ'D) FOR

CURING-TYPE SEALANT BETWEEN MULL

HALVES. AS SHOWN

IN DETAIL 2.

APPLY BOND BREAKER

TAPE TO SPLICE AT

LIVELOAD SPLICES ONLY.

SEAL JOINT BETWEEN MULLS

AT FACE AND SIDES

DETAIL 1

DETAIL 2

C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L