SSG 90 INSIDE CORNER FABRICATION

58

February 2012

Web Address: www.oldcastlebe.com

Phone: 1-866-OLDCASTLE (653-2278)

2 3/4"

2 1/8"

1 1/4"

CW-22

FS-43 (TYP)

FSW-324

@ HEAD &

SILL ANCHORS

ANCHOR HOLE (by others)

#17 (.173 dia)

DRILL THRU FOR

#12 FASTENER

TOP OF

HORIZONTAL

CW250-FP-7

CW250-FP-14

CW250-FP-13 (OPP SIDE)

CW250-FP-13

CW250-FP-14 (OPP SIDE)

1 1/4"

1 1/4"

1 1/8"

REF.

CW250-FP-92 MULL CAP

USE TOP & BOTTOM OF

MULL. ATTACH W/ FS-202

REF. SHT. 55 FOR ATTACHMENT