Ssg-135isc-seals, Ssg 135 inside corner weatherseals – Oldcastle BuildingEnvelope CW-250 User Manual

Page 66

Advertising
background image

SSG 135 INSIDE CORNER WEATHERSEALS

66

February 2012

C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L

Web Address: www.oldcastlebe.com

Phone: 1-866-OLDCASTLE (653-2278)

WEATHER SEALANT

STRUCTURAL GLAZING

SEALANT (CLEAN & PRIME

SURFACE AS REQ'D)

SEAL ADAPTORS @

BOTH ENDS & FULL

LENGTH (SEE

NOTE #1, SHT 57)

FS-322 @ 12" O.C.

NOTE:

HORIZONTAL CUT LENGTH =

WORKPOINT + 1 21/32"

HEAD AND SILL CUT LENGTH =

HORIZ. LENGTH - 1/16"

CW-3

(PRES. PLT)

1 1/8"

REF.

13/16"

1/2"

1/32"

FACE CAP

1 21/32"

1/8"

PRES. PLT.

CW-2

(FACE CAP)

CW-174 1/4" ADAPTOR

CW-168 1" ADAPTOR

CUT DLO - 1/16"

SEAL END OF HORIZONTAL

AND ADAPTOR TO FACE OF

MULLION.

CW-169 FACE CAP

V2110

MATCH DRILL MULL

THROUGH HOLES IN

ADAPTORS W/ #17 (.173 dia)

FOR #12 HH DRILL-FLEX.