Ssg-mull-horiz-install, Ssg mull - horizontal installation – Oldcastle BuildingEnvelope CW-250 User Manual

Page 46

Advertising
background image

SSG MULL - HORIZONTAL INSTALLATION

46

February 2012

Web Address: www.oldcastlebe.com

Phone: 1-866-OLDCASTLE (653-2278)

NOTE:
HORIZONTAL CUT LENGTH TO BE
D.L.O. - 1/16" WHEN HORIZONTAL IS
NOTCHED.

*NOTE: FACE OF HORIZONTALS AND

SSG MULLION DO NOT ALIGN

DUE TO SILICONE SPACE

REQUIREMENTS. SEAL

OFFSET AFTER ASSEMBLY.

*1/8

DRILL 7/32" CLEAR HOLE AND

C'SINK 7/16" DIA. FOR #12 PFH

3/4"

3/4" WHEN HORIZONTAL

IS NOT NOTCHED

SHEAR BLOCK PRIOR

TYP. SEAL AROUND
TO ASSEMBLY OF HORIZ.

CAP SEAL

FS-323

HORIZONTAL CUT

LENGTH = D.L.O.

CW250-FP-1

CW-1

CW-7

1-1/8"

11/16"

1/2"

4-1/2"

C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L

NOTE: CW-1 HORIZONTAL IS NOTCHED AT

TOP WHEN ABOVE EYE LEVEL. NOTCHED

AT BOTTOM WHEN BELOW EYE LEVEL. THIS

METHOD OF INSTALLING HORIZONTALS

SHOULD BE USED AT THE END OF A RUN.

CONVENTIONAL METHODS MAY BE USED

FOR THE REMAINING WALL.