135 INSIDE CORNER ASSEMBLY

O

41

February 2012

Web Address: www.oldcastlebe.com

Phone: 1-866-OLDCASTLE (653-2278)

CW-164

w/ CW-6

CW-165

CW-161

CW-23

CW-12

CW-12

CW-1

FS-42 (TYP)

CAP SEAL

NOTE:

DO NOT USE CW-13 OR CW-14

HORIZONTALS AT CORNERS.

3/4" TYP.

FS-322 @ 12" O.C.

SEAL TYP.

3/4"

DRILL 7/32" CLEAR HOLE AND

C'SINK 7/16" DIA. FOR #12 PFH.

USE HOLES IN HORIZONTAL TO

MATCH DRILL (#17 (.173 dia) HOLES

IN SHEAR BLOCKS.

*

*

CW250-FP-51

CW250-FP-50 (OPP SIDE)

CW250-FP-52 (TYP)

CW250-FP-50

CW250-FP-51 (OPP SIDE)

C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L