90 OUTSIDE CORNER GLAZING

O

33

February 2012

Web Address: www.oldcastlebe.com

Phone: 1-866-OLDCASTLE (653-2278)

NOTE:

1) COMPLETELY SEAL BOTH ENDS OF ADAPTOR TO HORIZONTALS;

MARRY SEALANT TO ADAPTOR LONGITUDINAL SEALS TO GLASS

SEALS.

2) REFERENCE SHEETS 31 THRU 32 FOR SHEARBLOCK, ANCHOR AND HORIZONTAL

DETAILS.

1/2"

1/32"

(FACE CAP)

2 1/2"

1 3/16"

1 3/8"

1/2"

WEATHER SEALANT

CONTINUOUS SEAL BETWEEN

ADAPTOR & MULLION

FS-119

(#10 X 1 3/8" PFH

STS) @ 18" O.C.

CW-37

SEAL ADAPTORS @

BOTH ENDS & FULL

LENGTH (SEE NOTE #1)

CW-17 GASKET

(SQUARE, BUTT

ENDS)

CW-34

CW-31

W/ CW-6

CW-1636

NOTE:

HORIZONTAL CUT LENGTH =

WORKPOINT - 3 11/16"

HEAD AND SILL CUT LENGTH =

HORIZ. LENGTH - 1/16"

CW-2 FACE CAP

CW-3 PRESSURE

PLATE

1/8"

(PRES. PLT.)

FS-322

@ 12" O.C.

CW-17

3 11/16"

NOTE: HORIZONTAL

FLUSH TO FACE

OF MULL

C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L