SPLICE SEALANT INSTRUCTIONS

29

February 2012

Web Address: www.oldcastlebe.com

Phone: 1-866-OLDCASTLE (653-2278)

3 3/4"

2"

1/2" MULL SPLICE

SEE NOTE "C"

2" DIA. X 3 3/4" LONG

"DENVER" FOAM ROD

1" DIA. X 3 3/4" LONG

"DENVER" FOAM ROD

SEE NOTE "A"

FOR SPECIAL

GLAZING TAPE

GENERAL NOTES:

A) NORTON "NORPRENE" P3247, 1/4" X 3/8" FOAM

GLAZING GASKET TO BE USED FOR LIVE-LOAD SPLICE

CONDITIONS IN LIEU OF CW-1636 FOAM TAPE INDICATED

ON STANDARD CW-250 DETAILS.

B) MULLION NORMALLY SPLICED IN 1/4" SPANDREL GLASS AREA.

C) MAXIMUM MOVEMENT OF ± 1/4" AT TYPICAL SPLICE

JOINT

DETAIL 3

DETAIL 4

1/4" GLASS

SEE NOTE "B"

C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L