25in-adapter-install, 1/4” adaptor fabrication & installation – Oldcastle BuildingEnvelope CW-250 User Manual

Page 21

Advertising
background image

1/4” ADAPTOR FABRICATION & INSTALLATION

21

February 2012

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com

CW-10 CUT LENGTH = D.L.O. + 1/2"

TYPICAL.

CW-10 CUT LENGTH

= D.L.O. TYPICAL

FS-322 @ 18" O.C.

USE COMPATIBLE SEALANT TO

MARRY JOINT BETWEEN SEALANT

AT GLASS, VERTICAL SEALANT

AT MULLION ADAPTOR, SEALANT

AT SHEAR BLOCK, AND HORIZONTAL

SEALANT AT ADAPTOR.

CAP SEAL ALL

FASTENERS

NOTE: CW-10 ADAPTOR IS SPLICED

AT MULLION SPLICE. REFERENCE

SHEET 31

CW-10 CUT LENGTH

= D.L.O. + 1"

NOTE: CUT LENGTH OF CW-10

AT CORNER VARIES. REFERENCE

CORNER DETAILS.

1"

1

2"

1

4"

DRILL 5/16" Ø

WEEP HOLE

WHEN USING CW-13 & CW-14;

THE CW-10 TO BE CUT D.L.O.

+ 1 1/2" AND WILL RUN THRU

VERTICALLY AT BOTH THE TOP

AND BOTTOM OF THE OPENING.

CW-13

CW-14

DETAIL FOR INSTALLATION

OF CW-10 AT CW-1 HORIZ.

WHEN USING CW-1; THE VERTICAL CW-10

WILL BE CUT D.L.O. + 1/2" AND WILL RUN

THRU AT THE BOTTOM OF THE LITE

AND THE HORIZONTAL CW-10 WILL RUN

THRU AT THE TOP OF THE LITE.

1

2" TYP.

C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L