MK Diamond MK-101-24 User Manual

Page 21

Advertising
background image

21

Prior to beginning work, a pre-start inspection of the saw should be performed.

1. To prevent the possibility electrical shock, the MK-101-24 MUST be de-

energized when connecting the Water Pump.

2. To prevent the possibility of electrical shock, use only MK Diamond qualified

replacement parts.

(A)

Ensure the ON/OFF Switch

is in the OFF position.

(B)

Verify the Movable Cutting

Table moves freely.

(C)

Inspect the Diamond Blade for

damage – verify the blade is

correct for the material being cut.

(D)

Inspect the Pump Assembly

for damage – ensure the cord

is free of cracks or cuts.

(E)

Inspect the MK-101-24

for damage – ensure the cord

is free of cracks or cuts.

(A)

Connect the Cooling Transfer

Tube to the inlet connection

of the Blade Guard.

(B)

Connect the Water Pump power

cord to the connection found on

the back of the motor.

WARNING

MK-101-24

SETUP

Pre-start Inspection

Connecting the Water Pump

NOTE:

To prevent pump damage, the Water Pump must be disconnected during

dry cutting operations.

Advertising