MK Diamond MK-101-24 User Manual

Page 23

Advertising
background image

23

When loosing the Cutting Head Adjusting Knob, the Cutting Head will pivot

down unless held.

(A)

Ensure the ON/OFF Switch

is in the OFF position.

(B)

Plug MK-100 into the GFCI.

(C)

Plug the GFCI into the

power source.

(A)

Loosen Cutting Head

Adjusting Knob.

(B)

Set cutting depth approximately

1/4 to 1/2 inch below the

surface of the Movable

Cutting Table.

(C)

Tighten the Adjusting Knob.

CAUTION

Set Cutting Depth

MK-101-24

SETUP

VOLTAGE:

120V

CYCLE:

60hz

PHASE:

1-phase

PORTABLE GENERATOR

ELECTRIC RECEPTACLE

4. I f using an extension power cord, make sure, the length and wire gauge cor-

respond to the requirements listed in on page 12. An extension power cord

that is too small in wire gauge (diameter), or too long in length, will cause the

motor to overheat and could cause premature failure.

5. Use an approved Ground Fault Circuit Interrupter (GFCI)

6. Do not cover the motor vents as this could lead to motor overheating.

In order to avoid breaker tripping, a 20-amp circuit breaker should be used.

A GFCI wall socket is the preferred protective device.

NOTE:

NOTE:

5 KW 120/240 volts 41.7/20.8 amps Single Phase

If using a portable generator, ensure the generator meets the following minimum requirements:

Advertising