Appendix a, Interface wiring, Audio connector wiring – 360 Systems DigiCart/EX User Manual

Page 75: Audio i/o interface table, Sync input, Caution

Advertising
background image

Appendix A

Interface Wiring

Audio Connector Wiring

XLR

BALANCED

UNBALANCED

PIN–1 GROUND

(SHIELD)

GROUND.

PIN–2

AUDIO " + "

AUDIO " + " OR "HOT"

PIN–3

AUDIO " – "

AUDIO " – " (SHIELD)
(JUMPER TO PIN–1 FOR GROUND REFERENCE)

SHELL GROUND

(NORMALLY NOT
CONNECTED)

GROUND

NOTE: If AC hum problems are encountered, disconnect the cable shields from pin–1 (cut the
jumper in unbalanced systems). Shield grounding will then be provided from the other end only,
and the path for a probable "ground loop" is broken.

CAUTION

Do not use "AC ground lifters" to solve hum problems.

A serious shock hazard may result.

A

UDIO

I/O

I

NTERFACE

T

ABLE

INTERFACE

DESCRIPTION

CONNECTOR

ANALOG

INPUT

Electronically Balanced

XLR-3F

ANALOG
OUTPUT

Phase Corrected Balanced

+20 dBu Maximum Signal Level

XLR-3M

AES/EBU (Professional)

XLR-3F

AES-3id-2000 75 OHM (Professional)

BNC female

DIGITAL

INPUT

IEC-958 TYPE II (Consumer)

BNC female

AES/EBU (Professional)

XLR-3M

AES-3id-2000 75 OHM (Professional)

BNC female

DIGITAL

OUTPUT

IEC-958 TYPE II (Consumer)

BNC female

S

YNC

I

NPUT

INTERFACE

DESCRIPTION

CONNECTOR

AES/EBU (Professional)

XLR-3F (Digital Input)

AES-3id-2000 75 OHM (Professional)

BNC female (Digital Input)

SYNC INPUT

REF IN (AES-11)

BNC female (REF IN)

33BInterface Wiring

63