Sensor amplifier, Sensor amplifier part names, Main screen – KEYENCE GV Series User Manual

Page 3

Advertising
background image

3

GV-IM-E

Sensor amplifier part names

*1

The reference surface (DATUM) detection indicator lights up when

performing reference surface detection. For more information, see

"Reference surface detection (DATUM) method (Application)" on page 5

of this Instruction Manual.

*2

The spot reflection indicator lights up during normal detection and turns off

during multiple reflection (when multiple peaks of received light intensity

occurs due to diffuse reflection), insufficient light intensity, and when the

target is out of the detection range.

*3

For more information about the CLP (clamp) function indicator, see "4.

Clamp function setting" on page 8 of this Instruction Manual.

*4

For more information about the timing input indicator, see "8. External

input setting" on page 8 of this Instruction Manual.

Main screen

The main screen can be switched between "Current/setting value display" and

"Peak/bottom value display". The main screen can be switched even during

keylock.

Pressing the [Up] and [Down] arrow buttons simultaneously on the main screen

forces the current value (red) to 0

*

.

* With the default settings. For details, see "9. Shift target value setting" on page 9

of this Instruction Manual.

When the channel No. 1 indicator is lit, the control output 1 (black line)
setting value is displayed. When the channel No. 2 indicator is lit, the
control output 2 (white line) setting value is displayed.
Operations are different in F-2 mode. (See page 5 of this Instruction
Manual.)

z

Current value and display resolution

In the default state, the current value shows 0 when the workpiece is located at

the maximum detection distance. Bringing the workpiece closer to the sensor

head gradually increases the value and displays it up to the minimum detection

distance.

The displayed values indicate guidelines for distances and should not
be used in the actual applications for measurement.

When using sensor head GV-H130

For example, when using the defaults with the setting value (green) at 500, the

comparator output turns on when the current value is 500 or greater and turns off

when it is less than 500.

If multiple reflection (when multiple peaks of received light intensity occurs due to

diffuse reflection) occurs during F-1, F-2, or A-1 modes, the value immediately

before the current value is held.

z

Setting value

The following table shows the default setting values for each channel.

z

Peak/bottom values

Peak value

:

Resets when the detection value exceeds the setting value

and holds the maximum value (peak value) until the

detection value falls below the setting value again.

Bottom value

:

Resets when the detection value falls below the setting value

and holds the minimum value (bottom value) until the

detection value exceeds the setting value again.

The held peak and bottom values can be cleared by pressing and hold

the [Up] arrow button.

Sensor Amplifier

Item

Current value

GV-H45 (L) GV-H130 (L) GV-H450 (L) GV-H1000 (L)

Detecting range (mm) 20.0 to 45.0 55.0 to 130.0

160 to 450

200 to 1000

Digital display (initial)

250 to 0

750 to 0

290 to 0

800 to 0

Display resolution

1

2

1

5

CLP

OUT

LASER

TIM

BANK

SET

SEL

MODE

1
2

1

2

1

spot

DATUM

series

Reference surface (DATUM) detection

indicator

*1

(red)

Current value display

(red)

Setting value display (green)

Spot reflection (1spot) indicator

*2

(green)

Arrow

buttons

Output status indicator

(red)

Laser radiation emission

indicator (green)

[SET] button

Channel No. indicator (green)

LED bar

CLP function indicator

*3

(red)

[MODE] button

Bank input indicator (green)

Timing input indicator

*4

(red)

DATUM

DATUM

DATUM

Setting value/current value display

Setting value (green)

Peak value (green) Bottom value (red)

Channel No. indicators

Current value (red)

Pressing the [MODE] button switches
the channels (channel No. indicators).

Peak value/bottom value display
Pressing the [UP] arrow button
resets the peak and bottom values.

Alternate

1
2

1
2

1
2

or

SET

MODE

SET

MODE

SET

MODE

Note

Note

Operation

mode

Item

Default value

GV-H45 (L)

GV-H130 (L) GV-H450 (L) GV-H1000 (L)

F-1, A-1,
A-2

Control output 1 (black)
(Channel 1 lit)

150

500

200

500

Control output 2 (white)
(Channel 2 lit)

125

400

150

400

F-2

Control output 1 (black) HIGH
(Channel 1 lit)

150

500

200

500

Control output 1 (black) LOW
(Channel 2 lit)

100

300

100

300

Control output 2 (white) HIGH
(Channel 1 flashing)

125

400

150

400

Control output 2 (white) LOW
(Channel 2 flashing)

75

200

50

200

Example

750

0

0mm

55mm

130mm

Current value

Distance

Minimum detection distance

Maximum detection distance

Reference