7

GV-IM-E

Keylock Function

The keylock function prevents accidental operation of the buttons during detection.

While using the keylock function, operations other than switching the display for the

main screen are prohibited.

The keylock settings can only be set in the main screen.

Setting/releasing keylock

While pressing the [MODE] button in the main

screen, press and hold the [UP] or [Down]

button for at least three seconds.

This sets (or releases) keylock and returns the

sensor to the main screen.

Interference protection function

The GV Series can prevent mutual interference that may occur when connecting

several expansion units.

The interference protection function only works when the following conditions are

met.

Interference protection functions on up to two adjacent units.

The main unit and expansion units use the same response speed.

The response speed is set to 1.5, 3, or 10.

Press and hold the [MODE] button for at least three seconds in the main screen

(during detection) to change the settings.

The screen shown to the right is displayed
during keylock and basic settings cannot be
input.

While configuring basic settings, pressing and holding the [MODE]

button for at least three seconds on any setting screen saves the

settings, ends basic setting, and displays the main screen.

Press the [Left] arrow button to return to the previous setting item.

Setting Each Type of Function

Note

During keylock

DATUM

SET

MODE

1
2

Note

DATUM

SET

MODE

1
2

DATUM

DATUM

DATUM

DATUM

DATUM

DATUM

DATUM

DATUM

SET

1
2

SET

1
2

SET

1
2

End of basic settings

MODE

MODE

MODE

MODE

Setting range: 1.5/3/10/20/50
(Unit: ms)

Setting range: noo/nCo/noC/nCC

1

Response speed

2

Output mode

Setting range: ON/OFF

When

is selected

Press

for about 3 seconds

Setting range: t-1oFF/oFd/ond/
Sht/ondoFd/ondSht

4

Clamp function

Setting range: F-1/F-2/A-1/A-2

3

Operation mode

or

MODE

or

MODE

or

MODE

or

MODE

or

MODE

or

MODE

or

MODE

or

SET

1
2

MODE

SET

1
2

MODE

SET

MODE

1
2

SET

MODE

1
2

SET

MODE

1
2

5

Delay timer 1 (Control output 1)

DATUM

DATUM

DATUM

DATUM

DATUM

DATUM

DATUM

DATUM

DATUM

DATUM

DATUM

DATUM

DATUM

End of optional settings

Setting range: Std/USr

7

Hysteresis

Setting range: oFF/SFt/bnK/tim

8

External input

Setting range: -199 to 999
(-198 to 998)

9

Shift target value

Setting range: nor/rEv

10

Distance display

Setting range: oFF/bAr/on

11

Eco display

Setting range: Varies depending
on the sensor head
model.

Hysteresis value

SET

MODE

1
2

Setting range: t-2oFF/oFd/ond/
Sht/ondoFd/ondSht

6

Delay timer 2 (Control output 2)

Setting range: 2 to 999 (Unit: ms)

Delay timer 1: Timer value T1

Delay timer 1: Timer value T2

Setting range: 2 to 999 (Unit: ms)

SET

MODE

1
2

Setting range: 2 to 999 (Unit: ms)

Delay timer 2: Timer value T1

SET

MODE

1
2

SET

MODE

1
2

SET

MODE

1
2

SET

MODE

1
2

SET

MODE

1
2

SET

MODE

1
2

SET

MODE

1
2

SET

MODE

1
2

Delay timer 2: Timer value T2

Setting range: 2 to 999 (Unit: ms)

SET

MODE

1
2

SET

MODE

1
2

SET

MODE

1
2

or

MODE

or

MODE

or

MODE

or

MODE

or

MODE

or

MODE

or

MODE

or

MODE

or

MODE

or

MODE

or

MODE

or

MODE

When

is selected

When

is selected

When

is selected

When

is selected

Reference