2 i/o communication, Selecting the dl-dn1 operating mode, I/o communication -4 – KEYENCE DL-DN1 User Manual

Page 32: Selecting the dl-dn1 operating mode -4, P. 3-4, I/o communication, Co mm u ni c a ting w ith t he fd -m h s er ie s

Advertising
background image

3-4

3

Co
mm

u

ni

c

a

ting
w

ith t
he FD

-M

H

s

er

ie

s

- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (FD-MH) -

3-2

I/O Communication

The device map varies depending on the operating mode of the DL-DN1. Select an operating
mode suited for the functions of the sensor amplifiers to be used, before accessing each device.
The memory in the DeviceNet master unit is linked to the buffer memory in the DL-
DN1 as shown below.

Select the DL-DN1 operating mode to suit the functions of the sensor amplifiers to be used.
The DeviceNet device configuration and the data available for I/O communication
vary, depending on the selected operating mode of the DL-DN1 and the number of
connected sensor amplifiers. An appropriate operating mode should be determined
by considering the memory occupied and the data that can be communicated.

"Occupied Memory" (page 3-5)

*1

It is possible to read instantaneous flow rate or rewrite setting value regardless
of the detection mode setting.

*2

This is not available with the FD-MH series.

Output data

Data here will be
reflected in the master unit.

Input data

Data here has been
output from the master unit.

DeviceNet master unit

DL-DN1

sensor amplifier

IN area

OUT area

I/O communication

I/O communication

Selecting the DL-DN1 Operating Mode

Available function of sensor
amplifier

Operating mode of DL-DN1

De
vice m

a

p

s

Co
m

m

u

ni

c

a

tion

meth

od

3-output

3-output + current value

5-output

5-output + current value

-

3-input

-

3-input

-

5-input

-

5-input

-

B

a

nk

S

e

tting

va

lu

e

-

B

a

nk

S

e

tting

va

lu

e

-

B

a

nk

S

e

tting

va

lu

e

-

B

a

nk

S

e

tting

va

lu

e

Read status

Yes

Yes

Yes

Yes

3-7 3-14

Read outputs
1 - 5

Output 1

3-9 3-14

Output 2

Output 3

(Not used)

No

No

(Not used)

Read current value
(instantaneous flow rate)*1

No

Yes

No

Yes

3-9 3-15

External
inputs
1 - 5

Integration reset

No

Yes

No

Yes

No

Yes

No

Yes

3-10 3-15

Flow rate hold
reset

(Not used)

Temperature
hold reset

No

No

(Not used)

Change bank number

No

*2

No

No

*2

No

No

*2

No

No

*2

No

-

-

Rewrite setting value*1

No

Yes

No

Yes

No

Yes

No

Yes 3-12 3-16