The following tables list the command parameters used in explicit messaging to read/
write the settings and status of sensor amplifiers and to issue motion commands.
For details about how the master unit performs explicit messaging using command
parameters, see:

"Issuing a Motion Command to a Sensor Amplifier" (page 3-19)

"Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-20)

Common Command Parameter List

The table below describes command parameters which are common to the DL-DN1.
InstID: Instance ID; AttrID: Attribute ID
Attribute R: Read; R/W: Read/Write

Command Parameter List

InstID
(DEC)

AttrID

(HEX)

Name

Description

Attribute

Data

type

Default

value

Parameter range

0

64

Status

Bit 0-12: Unused
Bit 13: Sensor ready
Bit 14: Warning state
Bit 15: Error state

R

WORD

0

*1

65

Error state

The error state values of sensor ampli-
fiers (ID 01 to ID 10) are output as
they are assigned to bits 0 - 9.

R

WORD

0

0: No Error
1: Error

66

Warning state

Not used with the FD-MH series.

R

WORD

0

-

67

System reserved

68

Current value
property

This property is output by assigning
sensor amplifiers (ID 01 to ID 10) bits
0 - 9. The output occurs when the
instantaneous flow rate is non-
numeric: "over," or "invalid."

R

WORD

0

0: Normally mea-
sured value
1: "over" or "invalid"

69 to 6B System reserved

6C

Error ID number Error details. If there are errors with

multiple ID numbers, the error infor-
mation for the smallest ID number is
output.

R

UINT

0

*2

6D

Error code

R

UINT

0

6E

Warning ID
number

Not used with the FD-MH series.

R

UINT

0

-

6F

Warning code

R

UINT

0

70 to 73 System reserved

74

Output 1

Output 1 is output by assigning sensor
amplifiers (ID 01 to ID 10) bits 0 - 9.

R

WORD

0

0: OFF
1: ON

75

Output 2

Output 2 is output by assigning sensor
amplifiers (ID 01 to ID 10) bits 0 - 9.

R

WORD

0

0: OFF
1: ON

76

Output 3

Output 3 is output by assigning sensor
amplifiers (ID 01 to ID 10) bits 0 - 9.

R

WORD

0

0: OFF
1: ON

77 to 8C System reserved

8D

Current value
"invalid"

If instantaneous flow rates from
sensor amplifiers (ID 01 to ID 10) are
invalid (-----), they are output by
assigning them to bits 0 - 9.

R

WORD

0

0: Normal value
1: Invalid