3 explicit messaging, Co mm u ni c a ting w ith t he fd -m h s er ie s – KEYENCE DL-DN1 User Manual

Page 56

Advertising
background image

3-3 Explicit Messaging

3-28

- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (FD-MH) -

3

Co
mm

u

ni

c

a

ting
w

ith t
he FD

-M

H

s

er

ie

s

Nx10+4

6C

Integrated flow
quantity unit

R/W

-

2

6D to

70

System reserved

71

N.O/N.C

R/W

-

0

Bit 0: Output 1 (1: N.C.)
Bit 1: Output 2 (1: N.C.)
Bit 2: Output 3 (1: N.C.)

72

Display mode

R/W

FD-MH10A

0

0: Std
1: rESo

FD-MH50A

1

FD-MH100A

1

FD-MH500A

0

73

Hysteresis

*7

R/W

FD-MH10A

0.10 0.00 to 9.99 *3

FD-MH50A

00.5 00.0 to 49.9 *3

FD-MH100A

01.0 00.0 to 99.9 *3

FD-MH500A 005.0 000.0 to 499.9 *3

74

Bank switching function

R/W

-

1

0: OFF
1: ON

75

System reserved

76

Flow rate zero function

R/W

-

0

0: OFF
1: ON

77

System reserved

78

Frequency mode

R/W

-

0

0: Standard
1: Frequency mode

79 to

7A

System reserved

7B

Power save mode

R/W

-

0

0: Do not use
1: Use

7C to

80

System reserved

81

Flow indicator color

R/W

-

1

0: Red for ON, green for OFF
1: Green for ON, red for OFF

82 to

83

System reserved

Nx10+5

64

Group-5 entry count

R

-

2

65 to

83

System reserved

Nx10+6

64

Group-6 entry count

R

-

11

65

Product Code

R

-

-

FD-MA*A: Main unit: 4004
FD-MA*A: Expansion unit: 4005
FD-MA*: Main unit: 4002
FD-MA*: Expansion unit: 4003

66

Revision

R

-

-

0101H to FFFFH

InstID
(DEC)

AttrID
(HEX)

Name

Description Attribute

Sensor

head

Default

value

Parameter range

Data

FD-

MH10A

FD-

MH50A

FD-

MH100A

FD-

MH500A

0

0.01

Cannot be set.

Cannot be set Cannot be set.

1

0.1

0.1

0.1

Cannot be set.

2

1

1

1

1

3

10

10

10

10

4

100

100

100

100

5

Cannot be set.

1000

1000

1000

6

Cannot be set Cannot be set Cannot be set.

10000