- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (FD-MH) -

Nx10+2

6B

Instantaneous flow rate
setting 3 (P3)

*7

R/W

FD-MH10A 13.00 00.00 to 30.00

FD-MH50A 065.0 000.0 to 100.0

FD-MH100A 130.0 000.0 to 200.0

FD-MH500A 400.0 000.0 to 999.9

6C

Instantaneous flow rate
setting 4 (P4)

*7

R/W

FD-MH10A 20.00 00.00 to 30.00

FD-MH50A 100.0 000.0 to 100.0

FD-MH100A 200.0 000.0 to 200.0

FD-MH500A 500.0 000.0 to 999.9

6D to

83

System reserved

Nx10+3

64

Group-3 entry count

R

-

5

65

Key lock function

R/W

-

0

0: Deactivate key lock
1: Key lock

66

System reserved

67

Analog output selection

*10

R/W

-

0

0: Standard
1: Free range analog

68

Free range analog
upper limit

*10

R/W

FD-MH10A

10.0 0.0 to 30.00 (Settable unit: 0.1)

FD-MH50A

050

000 to 100 (Settable unit: 5)

FD-MH100A

100

000 to 200 (Settable unit: 10)

FD-MH500A 0500 0000 to 1000 (Settable unit: 50)

69

Free range analog lower
limit

*10

R/W

FD-MH10A

0.0

0.0 to 30.00 (Settable unit: 0.1)

FD-MH50A

000

000 to 100 (Settable unit: 5)

FD-MH100A

000

000 to 200 (Settable unit: 10)

FD-MH500A 0000 0000 to 1000 (Settable unit: 50)

6A to

83

System reserved

Nx10+4

64

Group-4 entry count

R

-

29

65

System reserved

66

Detection mode

R/W

-

0

0: F-1
1: F-2
2: F-3
3: A-1
4: A-2

67

System reserved

68

Response time

R/W

-

3

0: 0.05 s
1: 0.1 s
2: 0.5 s
3: 1.0 s
4: 2.5 s
5: 5.0 s
6: 10.0 s
7: 30.0 s
8: 60.0 s

69

Average display

*11

R/W

-

1.0

00.0 to 10.0 (in steps of 0.5)

6A

Time-out time for
output 2

R/W

-

10

1-99

6B

Integration direction

R/W

-

0

0: Increment
1: Decrement

InstID
(DEC)

AttrID
(HEX)

Name

Description Attribute

Sensor

head

Default

value

Parameter range