Functions sensitivity setting – KEYENCE LK-2000 Series User Manual

Page 15

Advertising
background image

15

Sets an appropriate sensitivity according to the change in target surface
condition.

Set the sensitivity to AUTO for normal use.

AUTO:
Used to measure various objects: from objects with low reflectance such
as black rubber, to ones with high reflectance such as metals.

Note: If the reflectance of the target changes greatly during a short
cycle, the analog output may become unstable with the AUTO setting.
In this case, set the sensitivity to HIGH or LOW.

HIGH:
Fix the sensitivity to high. Used to measure a part with low reflectance
(black) in the above condition.

LOW:
Fix the sensitivity to low. Used to measure a part with high reflectance in
the above condition.

FUNCTIONS SENSITIVITY SETTING

Example: Measurement of pin warpage
In the measurement of the warpage of moving pins, the reflectance of
the pin and gap change greatly during a short cycle. To measure such a
target, set the sensitivity setting switch to LOW and measure only pins
which have high reflectance.

Output waveform obtained with AUTO

Output waveform obtained with LOW

HIGH

AUTO

LOW

GAIN

LK

-031