The LK-501/503 offers two measurement modes to be used according to
the measurement conditions.

Long-range mode
Measures within a range of 250 to 750 mm.
Use long-range mode to mount the sensor head at a distance from the
target, or to obtain a long measurement range.

High-precision mode
Measures within a range of 250 to 450 mm.
Use high-precision mode to obtain high repeatability.

Mode selection

Hold down the UP key for the SHIFT adjustment, and turn the key-
operated laser switch from OFF to ON. This changes the measurement
mode.

Note: The measurement mode is factory-set to long-range mode.
The measurement mode is toggled every time the above operation is
performed.
Long-range mode

➞ High-precision mode ➞ Long-range mode ➞

High-precision mode....

Mode confirmation

Press the ZERO/RESET key for the SHIFT adjustment and the RESET
key for the SPAN adjustment simultaneously. The indicators illuminate to
show the current measurement mode.

FUNCTIONS MEASUREMENT MODE SELECTION [WITH LK-501/503 ONLY]

When long-range mode is set:
Status of indicators

All five indicators illuminate.

When high-precision mode is set:
Status of indicators

Three indicators, BRIGHT, DARK, and LASER ON, illuminate.

TIMING

STABILITY

BRIGHT

DARK

LASER ON

TIMING

STABILITY

BRIGHT

DARK

LASER ON