Mutual interference, Dimensions, Sensor head – KEYENCE LK-2000 Series User Manual
Page 23: Interference range
Advertising
23
Sensor head
LK-031/036
DIMENSIONS
Unit: mm
85
76
67
40°
25 to 35
13.5
4
25
26
13
ш7
ш15
43
500
2 x ø4.5
(mounting
hole)
LK-081/086
95
76
67
25°
65 to 95
13.5
4
25
36
18
ш7
ш15
43
500
2 x ø4.5
(mounting
hole)
MUTUAL INTERFERENCE
Interference range
Interference will occur only when the beam spot of another sensor is
positioned inside of the shadowed area.
LK-031/036
LK-081/086
LK-501/503
12 mm
46 mm 34
mm
8 mm
10 mm
±1 mm
LK-031
30 mm
95 mm 65 mm
15 mm
13 mm
35 mm
±3 mm
LK-081
26 mm
750 mm
524 mm
226 mm
152 mm 19 mm
±2.4 mm
LK-501
;
;