2: Prepare for Installation
2-3
Customer-Supplied Items for both sensors:
Tape measure
Marking pen
Tapping fluid
Level
Tap handle
Tape (electrical or masking)
Degreaser (isopropyl alcohol or acetone)
Caulking gun
Digital Multimeter (DMM)
Notes
• If sensors will be installed by KM, our service technician
will bring this equipment on-site as part of their tool kit.
• If sensors will be installed by the customer, purchase of a
KM Test Meter is highly recommended to simplify
installation.
• If the drill motor is not purchased from KM, it must
meet the following minimum specifications:
3/8” (for metal drilling), variable speed
reversing, 0-2500 RPM.
The following additional equipment is used to install Microcells:
Optional Installation Kit* #39-2012-0X, each complete with:
Microcell drill template with #8-32 socket head cap screw
9/64” Hex T-handle driver
#29 drill bits
#8-32, 2-flute, spiral-point taps
Sikaflex 1A polyurethane sealant and Material Safety Data
Sheet (MSDS)
Rust-inhibiting silicone grease
(for carbon steel surface only)
KM Test Meter (optional)
Drill motor (optional)
* Kit items are also
available individually.
Microcell Installation Equipment