Mounting the l-cell – Kistler-Morse KM L-Cell Bolt-On User Manual

Page 18

Advertising
background image

Chapter 3. L-Cell Installation on Vertical Legs

3-4

1.

Wipe down a 5” by 2

1

/

4

” (127 by 57mm) surface, centered on the

template mounting hole, with degreaser. This cleans the bare
metal and adjacent mounting surface for the environmental cover.

2.

Apply a thin coat of KM rust inhibitor to the bare metal surface
for the L-Cell. (Fig 3-10)

3.

Connect the L-Cell’s red, black, and white wires to the corre-
sponding terminals on the KM Test Meter. Turn on the power to
the Test Meter and set the Simulate/Test switch to the Test
position. (Fig 3-11)

Note

If a KM Test Meter is not available, refer to Appendix G,
Alternate Method for Checking Output, before proceeding.

4.

With the cable end down, align an L-Cell with its mounting holes.
Fasten the L-Cell loosely to the leg using the three #6-32 x

5

/

8

socket head cap screws. Do not tighten the screws. If the voltage
goes outside the range -200 to +200 mV, immediately loosen the
screw(s).

4.

Drill the L-Cell mounting holes with the #36 drill bit,
using the template guides (Fig. 3-9) as follows:
A. Drill hole #2.
B. Insert a spare drill bit through hole #2 in the
template to hold the template securely in place.
C. Drill hole #1 and #3. Remove the spare drill bit from
hole #2.

5.

Tap the mounting holes:
A. Loosen the screw securing the template and rotate
the template until the tap guide is aligned with hole
#1. Retighten the screw.
B. Using the tap guide, thread hole #1 with the #6-32
tap.
C. Repeat steps A and B for hole #2 and #3.

6.

Repeat Surface Preparation and Drill/Tap for the
second L-Cell.

7.

Remove burrs from all the holes created.

Mounting the L-Cell

CAUTION

Do not install L-Cells in
the rain.
Do not trap moisture under
the environmental cover.

CAUTION

Do not apply rust inhibitor
beyond this area, or the
environmental cover will
not adhere properly.

Fig. 3-10: Apply rust inhibitor.

Fig. 3-11: Test L-Cell

Figure 3-9. Drill and Tap Template

Template Mounting Hole
(mount here with #6-32 x 1

5

/

8

” screw)

0° Level
Bubble

45°

Level

Bubble

Notes:
1. After L-Cell mounting holes drilled, rotate template to

use tap guide to tap holes.

2. Holes #4 and 5B and 45° bubble not used for this

application.

2

3

1

4

5A

5B

Tap Guide

Drill Guide
(typical,
# 1, 2, and 3)

Advertising