Chapter 3. L-Cell Installation on Vertical Legs

3-2

Figure 3-4. Vertical Location of L-Cell Sets

for Legs with Braces and with Free Leg

greater than MinH

L-Cell sets
mounted at
mid-height of
free leg
(typical)

Alternate
location —

L-Cell sets
mounted at
mid-height of
free leg at
top (typical)

Support Legs without X-Braces

See Figure 3-3.

If the free leg distance (length between foundation and the vessel) is
between minH (see Note) and 11’ (3.4m), mount the L-Cell sets at mid-
height of the free leg.

If the free leg distance is more than 11’ (3.4m), mount the L-Cell sets at
5’6” (1.7m) above the foundation.

If the free leg distance is less than minH, this is a special application
situation. Consult KM before proceeding further.

Support Legs with X-Braces

See Figure 3-4. If the free leg distance is minH or more, mount the L-Cell sets
at mid-height of the free leg.

Measure the free leg between the bottom of the lower x-brace or
horizontal brace and the top of the foundation.

For an alternate location, measure the free leg between the top of the
upper x-brace or horizontal brace and the beam supporting the vessel.

See Figure 3-5. If the free leg distance is less than minH, mount the L-Cell
sets at the mid-height between the lowest braces.

Figure 3-3. Vertical Location of

L-Cell Sets for Legs without Braces

‘Free Leg’ H >
MinH

Minimum of

1

/

2

H

or 5’6” (1.7m)

L-Cell set
mounted at
lower of
mid-height of
free leg or
5’6” (1.7m)
(typical)

Figure 3-5. Vertical Location of L-Cell Sets for Legs with Braces and with Free Leg

less than minH

H

1

/

2

H

L-Cell set
mounted at
mid-point
between
lowest
braces
(typical)

‘Free Leg’
less than
minH

Alternate ‘Free
Leg’ less than
minH

H

1

/

2

H

‘Free Leg’
less than
minH

Alternate ‘Free
Leg’ less than
minH

L-Cell set
mounted at
mid-point
between
lowest
braces
(typical)

‘Free Leg’

H > MinH

1

/

2

H

‘Free Leg’

H > MinH

1

/

2

H

(Cont. Vertical Location of L-Cell Sets)

Note

minH is defined as the
minimum free height to
install sensors. The
height should be three
times the beam width or
12” (305 mm) , whichever
is highest of the two.