Chapter 4. L-Cell Installation on Horizontal Beams

4-2

# of Support

Points for

Description

Each Vessel

Single vessel — no diagonal beam supports

4

Multiple vessels — no diagonal beam supports,

4

no common beams or common vertical legs

Single vessel — diagonal beam supports,

4

weight supported by diagonal beams only

Single vessel — diagonal beam supports,

8

weight supported by horizontal and
diagonal beams

Multiple vessels — diagonal beam supports,

8

weight supported by horizontal and diagonal
beams, no common beams, common
vertical legs

Multiple vessels — no diagonal beam supports,

4

common internal lateral beams, common
internal vertical legs
(Note: This application will produce some
degree of interference between vessels.)

Multiple vessels — no diagonal beam supports,

4

independent internal lateral beams, common
longitudinal beams
(Note: This application will produce some
degree of interference between vessels.)

Multiple vessels — diagonal beam supports,

8

weight supported by horizontal and
diagonal beams, common internal lateral beams,
common internal vertical legs
(Note: This application will produce some
degree of interference between vessels.)

Series 500 — Independent Beams

501

502

502

502

552

553

553

553

551

602

602

601

601

601

651

651

651

Series 600 — Common Horizontal Lateral
and/or Longitudinal Beams

Notes

:

1.

Illustrations for Series 501, 502, 551, 552, 553, and 651 show
L-Cells in relationship to the load points.

2.

If your application differs from the above, contact K-M for
application assistance.

Figure 4-2. L-Cell Mounting Locations

Legend:

= vertical leg

= vessel support point

= mounting location for L-Cell set