Chapter 5. L-Cell Installation on Skirt-Supported Vessels

5-7

Mark Locations

(Bolted, Skirt-Supported Vessels)

1.

Beginning on the outside of the skirt at the door panel (panel 1), walk
clockwise to panel 2. Mark the preliminary L-Cell location:
• Locate the L-Cell on the panel horizontal centerline.
• Vertically, locate the L-Cell at the panel mid-height (typically 3’ to 4’

[0.9 to 1.2m] above the foundation).

• Minor obstructions — Move the L-Cell so it is not within 2’ (0.6m) of

a minor obstruction. Vertically, center the L-Cell within the effective
panel height.

• Major obstructions — Move the L-Cell to the centerline of the next

panel to avoid major obstructions.

2.

Continuing to move clockwise around the outside of the skirt, repeat
Step 1, marking preliminary mounting locations on panels 4, 6, etc.

Figure 5-9. Mounting L-Cells in Alternate Locations because of Minor Obstructions

Maintain 2’ (0.6m) Minimum Distance between

L-Cells and Minor Obstruction (seam weld)

Modified Location to

Avoid Placement

of L-Cells near

Minor Obstruction

‘Ideal’ Locations, based
on Symmetrical Spacing

Seam
Weld

Major Obstruction Example

on Bolted Vessel

Figure 5-8. Mounting L-Cells in Alternate Locations because of Major Obstructions

Do not install L-Cells within 4’ (1.2m) of major
obstruction. Install as shown on Modified layout below.

Major Obstruction

at Ideal Location
for an L-Cell Set

Mount L-Cells
4’ (1.2m)
from Major
Obstruction

Welded Vessel

Do not install L-Cells on same panel as major
obstruction (panel 8). Install on center of adjacent
panel, as shown on Modified layout below.

Panel 8

Panel 9

Bolted Vessel

Major Obstruction Example

on Welded Vessel

18’ (5.5m) Diameter

Modified Layout because

of Major Obstruction

1

2

3

4

5

6

7 8

9

11

Mount L-Cells on Panel 9
instead of Panel 8

12

10

1

2

3

4

5

6

7

8

9

10

11

12

18’ (5.5m) Diameter

Typical Layout

18’ (5.5m) Diameter

Typical Layout

18’ (5.5m) Diameter

Modified Layout because

of Major Obstruction

Mount L-Cells 4’ (1.2m)
from Major Obstruction

Note

The procedure for marking
mounting locations is based on
the nominal locations shown.
Refer to the Application Data
Form for the approximate
mounting locations selected by
KM.