Chapter 5. L-Cell Installation on Skirt-Supported Vessels

5-19

Figure 5-40. Wiring Junction Boxes Together (inside view of skirt) — Conduited Installation

Enlarged view of
connections to TB1
and TB2

Connect
3-Conductor
Cable to TB2

Connect 3-Conductor

Cable from Junction

Box on Panel 3 to TB1

Connect
another
3-Conductor
Cable to TB2

Connect Shield Wire

to Shield Terminal

Connect Shield Wire

from Both Cables to

Shield Terminal