Installation Instructions

Read these instructions completely and carefully.

[^Connect the Range to the Gas Supply

Shut off the main gas supply valve before disconnecting the old range and leave It off until the new hookup has

been completed. Don't forget to relight the pilot on other gas appliances when you turn the gas back on.

Because hard piping restricts movement of the range, the

use of a CSA International-certified flexible metal appliance
connector is recommended unless local codes require a
hard-piped connection.

Never use on old connector when installing a new range. If the
hard piping method is used, you must carefully align the pipe;

the range cannot be moved after the connection is made.

To prevent gas leaks, put pipejoint compound on, or wrap pipe

thread tape with Teflon* around, all male (external) pipe threads.

Install a manual gas line shut-off valve in the gas line in
on easily accessed location outside of the range. Moke
sure everyone operating the range knows where and
how to shut off the gas supply to the range.

Install male 1/2" flare union adapter to the 1/2" NPT
internal thread elbow at inlet of regulator. Use a backup

wrench on the regulator fitting to avoid damage.

When installing the range from the front, remove the 90°

elbow for easier installation.

Install male 1/2" or 3/4" flare union adapter to the NPT
internal thread of the manual shut-off valve, taking care

to backup the shut-off valve to keep it from turning.

P

Connect flexible metal appliance connector to the
adapter on the range. Position range to permit
connection at the shut-off valve.

When all connections have been made, make sure all

range controls are in the off position and turn on the
main gas supply valve. Use a liquid leak detector at all

joints and connections to check for leaks in the system.

AWARNING

Fire Hazard: Do not use a

flame to check for gas leaks.

When using test pressures greater than 1/2 psig to pressure

test the gas supply system of the residence, disconnect the

range and individual shut-off valve from the gas supply piping.

When using test pressures of 1/2 psig or less to test the gas

supply system, simply isolate the range from the gas supply
system by closing the individual shut-off valve.

*Teflon: Registered trademark of DuPont

Flexible Connector Hookup

Pressure

regulator

X

Installer: Inform
the consumer of

1/2" or 3/4"

the location of the

gas shut-off valve.

Gas pipe---- >

'Ll

Adapter

Gas

shut-off
valve

Rigid Pipe Hookup Options

45° Elbow

90° Elbow

Black

Iron pipe

Union

Union

Installer: Inform the consumer of
the location of the gas shut-off
valve.

Nipple

Gas

shut-off
valve

1/2" o

3/4"Gas pipe

Alternate

Hookup

90° Elbow ■

Nipple ■

Gas

shut-off ■

valve

1/2" or 3/4"

Gas pipe '

Adapter

90° Elbow

Nipple

Quick connect

or union

Nipple

Pressure

regulator

90° Elbow

Installer: Inform the consumer of
the location of the gas shut-off
valve.

45