Installation Instructions

Read these instructions completely and carefully.

g]

Replace the Power Cord (Optional) Continued

Perform this step only if the power cord shipped on the range does not match your wall receptacle.

3-Wire Power Cord Installation Option

A

WARNING

The neutral or ground wire of the

power cord must be connected to the neutral terminal

located In the center of the terminal block. The power leads

must be connected to the lower left and the lower right
terminals of the terminal block.

Locate the copper ground strap on the lower back of the
range.

Loosen the upper center screw on the terminal block.

Slide the open slotted end of the ground strap under the

upper center screw on the terminal block. Make sure the

ground strap is all the way against the upper center screw
and tighten it in place.

Place the ground plate (removed earlier) over the bottom

of the ground strap, press them against the range frame
and attach them with the ground screw (removed earlier).

Insert the new power cord through the strain relief. Allow

enough slack to easily attach the wires to the terminal

block.

Insert the 3 terminal screws (removed earlier) through

each power cord terminal ring and into the lower

terminals of the terminal block. Be certain that the center

wire (white/neutral) is connected to the center lower

position of the terminal block. Tighten screws securely

(approximately 20 inch-lbs.) into the terminal block.

Secure the strain relief in place in the bracket by tightening

the strain relief screws.

Ground strap

\