Installation Instructions

Read these instructions completely and carefully.

\5\ Replace the Power Cord (Optional) Continued

Perform this step only if the power cord shipped on the range does not match your wall receptacle.

4-Wire Conduit Installation Option

Remove the strain relief clamp from the bracket.

2

m

Assemble the squeeze connector (obtained locally),

matching the diameter of your conduit, in the bracket
hole. Insert the conduit through the squeeze connector.

Allow enough slack to easily attach the wires to the

terminal block.

NOTE- Do not install the conduit without a squeeze

connector.

Insert the ground bare wire tip between the range frame

and the ground plate (removed earlier) and secure it in

place with the ground screw (removed earlier). Insert the
bare wire (white/neutral) tip through the bottom center of

the terminal block opening. Insert the two side bare wire
tips into the lower left and the lower right terminal block

openings. Tighten the screws until the wire is firmly secure

(approximately 20 inch-lbs.).

NOTE Make sure the wire is completely inserted into the

terminal block and a secure connection is made.

Secure the squeeze connector in place in the bracket by

tightening the squeeze connector screws.

NOTE ALUMINUM WIRING:

Aluminum building wire may be

used but it must be rated for the correct amperage and voltage

to make connection.

Wire used, location and enclosure of splices, etc., must

conform to good wiring practices and local codes.