Installation Instructions

W\ Replace the Power Cord (Optional) Continued

Perform this step only if the power cord shipped on the range does not match your wall receptacle.

[2

3-Wire Conduit Installation Option

Locate the copper ground strap on the lower back of the

range.

Loosen the upper center screw on the terminal block.

Slide the open slotted end of the ground strap under the

upper center screw on the terminal block. Make sure the

ground strap is all the way against the upper center
screw and tighten it in place.

Place the ground plate (removed earlier) over the bottom

of the ground strap, press them against the range frame
and attach them with the ground screw (removed
earlier).

Remove the strain relief clamp from the bracket.

Assemble the squeeze connector (obtained locally),

matching the diameter of your conduit, in the bracket
hole. Insert the conduit through the squeeze connector.

Allow enough slack to easily attach the wires to the
terminal block.

NOTE:

Do not install the conduit without a squeeze

connector.

Insert the center bare wire (white/neutral) tip through the
bottom center terminal block opening. On certain
models, the wire will need to be inserted through the

ground strap opening and then into the bottom center

block opening. Insert the two side bare wire tips into the
lower left and the lower right terminal block openings.

Tighten the screws until the wire is firmly secure
(approximately 20 inch-lbs.).

NOTE:

Make sure the wire is completely inserted into the

terminal block and a secure connection is made.

Secure the squeeze connector in place in the bracket by

tightening the squeeze connector screws.

NOTE: ALUMINUM WIRING:

Aluminum building wire may be

used but it must be rated for

the correct amperage and voltage to make connection.

/

Ground strap

o

■ Open slotted end

Wire used, location and enclosure of splices, etc.,

must conform to good wiring practices and local
codes.