Appendix C Troubleshooting

Troubleshooting the Boot Process

OffDM Verification of the Boot Configuration Record and Disk

During OffDM, the CSS checks the configuration record and initializes the disk.
The following sections discuss:

Errors in the Boot Configuration Record

Failure of the Disk Drive in the SCM

Errors in the Boot Configuration Record

If the CSS detects any errors in the configuration record, a failed message appears
along with information on the configuration parameter in question. The problems
may include a misconfigured IP and subnet address, or there is no primary or
secondary boot record. The CSS does not continue the boot process until the
problem is resolved.

If a failed message occurs:

1.

Enter the OffDM menu and display your current configuration record. For
detailed information on using OffDM, refer to the Cisco Content Services
Switch Administration Guide
.

2.

Correct the misconfiguration.

3.

Reboot the CSS.

Note

If a MAC address error occurs, obtain technical assistance.