Troubleshooting the css 11501, Table c-4 – Cisco 11500 Series User Manual

Page 149

Advertising
background image

C-19

Cisco 11500 Series Content Services Switch Hardware Installation Guide

78-13884-03

Appendix C Troubleshooting

Troubleshooting the CSS 11501

Troubleshooting the CSS 11501

CSS 11501 status is indicated by the Status LED on the front panel. For
information about the CSS 11501 LEDs, refer to Chapter 2,

Cabling the CSS

.

Table C-4

provides suggestions for correcting problems that may occur with the

CSS 11501.

Table C-4

Troubleshooting the CSS 11501

Symptom

Recommended Action

At boot up, the following
message appears:

CHMGR: Slot slot/subslot

had diagnostic failures -

NOT STARTING UP

When there is a failure on a CSS 11501
component, the CSS 11501 attempts the boot
process three times. If the boot is unsuccessful,
the CSS generates a log message and saves it in
the boot.log file. Obtain technical assistance.
Refer to the

“About This Guide”

. For

information on log files, see

“Log File

Information”

.

During normal CSS operation,
the following message appears:

Temperature has reached x

celsius for slot number

Check the six fans in the chassis. The
CSS 11501 is running at a temperature that is
too high, as indicated by the x variable. When a
fan failure occurs, obtain technical assistance.