Rs232 connection, Rs485 single connection – FingerTec Q2 User Manual

Page 46

Advertising
background image

45

Comm Opt

u

4RS232 Yes
RS485

Yes

Note

When RS232 function

is enabled, the Ether-

net will be disabled.

Comm Opt

u

4

RS232 Yes

4RS485 Yes

Note

When RS485 func-

tion is enabled, the

Ethernet will be

disabled.

Note

The RS232/ 485

converter is an op-

tional component.

Q2 Reader

C2 Controller

RS232 cable

PC

RS232 Connection

1. Setup of RS232

Access to Menu, select “Options” > “Comm. Opt” > “RS232”, select
“Yes” to enable RS232 function.

2. Turn off the reader.
3. Plug the RS232 cable to the RS232 port of the PC.
4. Plug the RS232 other end to the RS232 joint.
5. Turn the power on.

RS485 Single Connection

1. Setup of RS485

Access Menu, select “Options” > “Comm. Opt”
> “RS485”, select “Yes” to enable RS485
function.

2. Turn off the reader.
3. Plug the RS485 cable extender to the connector. Connect another

end of the cable to the RS232/485 data converter.

4. Connect the RS485 data converter to the RS232 port of PC.
5. Turn the power on.