12 • access, Most commonly used access features – FingerTec Face ID 4d User Manual

Page 27

Advertising
background image

2

12 •

ACCESS

(Face ID 4dd only)

Most Commonly Used Access Features

The Face ID dd can be connected to door access accessories like electromagnetic

lock and doorbolt to control access to doors. FingerTec provides all kinds of doorlock

accessories which can be viewed at accessory.fingertec.com. Under Access Control

Parameter In Access icon, you can configure  most common used functions, which

are explained below. To access to Access Control Parameter: Menu > System > Access

Control Settings > Access Control Parameter

how Long it taKes BeFore the door LoCKs again

(Lock Delay)

This value is the time period for the door to lock again after it unlocks on a successful

verification. The default value is 10 seconds and the range is between 1 to 10. A tap

on the value will prompt a keypad. Input the value in seconds.

deLaying door sensor

(Door Sensor Delay)

This function only works if a door sensor is available. When a door does not close for

a specified time, the sensor will trigger alarm system. Specify the time of the delay.

Default value is 10s, the range is 0-99 s. A tap on the value will prompt a keypad. Input

the value in seconds.

Choosing door sensor type

(Door Sensor Mode)

There are two types of door sensors available for door access which are Normally Open

(NO) and Normally Close (NC). Once a door sensor is available, you have to choose the

door sensor type. Default is None.

deLaying aLarM

(Alarm Delay)

This function only works when there is alarm system installed with Face ID d. You can

adjust the time before Face ID d triggering an alarm system if the door is not closed.

A tap on the value will prompt a keypad. Input the value in seconds. The default value

is 5s.

Advertising