Wiring diagrams, Siren to alert time attendance reporting, Installation – FingerTec AdapTec TA User Manual

Page 2

Advertising
background image

4

5

6

1

2

4

INPUT : AC

110

~

240V

OUTPUT :

DC

12V

3A

3

Identify a location to mount the
AdapTec TA on a wall.

Fix the AdapTec TA onto the wall
by tightening the screws into the 4
holes.

Remove the L-shape piece from the AdapTec TA

Open the cap, look for the part shown in
the diagram and you will see 2 holes.

Install the piece to the AdapTec TA

The other 2 holes at the bottom

Mount the AdapTec TA on a wall

WIRING DIAGRAMS

(TA100 & 100C Series / AC100 / TimeLine 100)

STEP 1 •

Connection Points

STEP 2 •

Connect AdapTec TA to a Power Source

Now you can turn on the power source and start to use the terminal for time attendance.

SIREN TO ALERT TIME ATTENDANCE REPORTING

Benefits of using AdapTec TA with Siren

We recommend you to install the terminal using AdapTec TA, as an additional
port is readily built to receive the signal from FingerTec terminals. AdapTec TA is
outputs DC12V to connect to a siren. You do not need to source for an additional
DC12V power supply for this purpose.

FUNCTION • TA100 Series

The AdapTec TA is integrated to support the scheduled siren function. You can connect a bell with
the DC12V max 1A to an AdapTec TA. TA100 series is equipped with 10 scheduled bell function.
You can preset the scheduled bell inside the TA100 series by connecting the TA100 series siren
relay to the AdapTe TA.

AdapTec TA

Power Output Module

DC 12V

Rechargeable

Backup
Battery

ESC

MENU

1

4

7

2

5

8

0

3

6

9

ok

Red

Blue

Green

Power Supply/Power Input Module

AC110~240V

L - Live

N - Neutral

E - Earth

L

N

E

-V

+V

5V

Output

Input

Siren To Battery

OK

Max

1A

5V

0

C

NO

12V

0

---

+

Connection points in

TA100 Series / AC100 / TimeLine 100

AdapTec TA

Power Output Module

DC 12V

Rechargeable

Backup Battery

5V

Output

Input

Siren To Battery

OK

Max

1A

5V

0

C

NO

12V

0

---

+

Siren

TA100 Series

Siren relay

*Siren relay integrated on mcu

INSTALLATION

How to mount an AdapTec TA onto a wall

Attach the L-shape to the AdapTec TA as
shown and tighten the screws.

After removing the piece, you will have
one L-shape piece and 2 screws.

Find an L-shape piece at the top right of an
AdapTec TA . This piece is attached to the
AdapTec TA by 2 screws.

Advertising